LWL-VA-PoE+
Disappears
inside the column.
No box on the wall, no box on the column — the box INSIDE the column. It is pushed in through the inspection opening of an existing lighting column and cannot be seen from outside. Hence the unusual format: 500 mm high, 110 mm wide.
01DIN rail
The equipment clips onto a DIN rail. It takes barox devices with four or eight PoE ports, unmanaged up to Layer 3 — which switch goes in depends on the number of cameras and the power class: two to a maximum of four IP cameras, with PoE, PoE+ or PoE++.
02Terminal blocks
The terminals are marked L1, N and PE, with the green-yellow earth conductor beside them. This is where the mains supply comes in.
03Splice cassette
The fibre lies coiled on a cassette, held by clips. The coil is the slack reserve — the length a splice needs. At 110 mm wide it is the part that sets the space.
04Media converter
A barox PC-PMC101-GME. Its type plate lists 1 × 10/100/1000 PoE+, 1 × 100/1000FX-SFP, 48–56 V DC and −40 to +75 °C.
Drag to turn.
500 mm tall, 110 mm wide — that is what gets it through the inspection opening and out of sight. Two to four cameras on one switch.
Installation location
Inside the column
Slid into an existing lighting column through its inspection opening.
Before ordering: measure the opening
The box only fits if the inspection opening measures at least 550 × 115 mm and the column leaves 250 mm of depth clear inside. That is the first figure we need for an enquiry — everything else follows from it.
Switches to choose from
The DIN rail takes barox devices with four or eight PoE ports, unmanaged up to Layer 3, with PoE++ up to 90 W per port. Which one goes in depends on the number of cameras and the power class.
Technical data
Series LWL-VA-PoE+ · figures per the ETEC product catalogue. Equipment depends on configuration.
- External dimensions
- 500 × 110 × 170 mm (H × W × D)
- Enclosure
- Stainless steel 1.4301
- Bracket
- 2 mounting brackets in V2A
- Protection rating
- IP 66
- Cameras
- 2 to max. 4 IP cameras
- PoE standard
- PoE / PoE+ / PoE++ via the built-in switch
- Installation location
- Inspection opening of a lighting column
- Minimum opening size
- H 550 mm · W 115 mm · D 250 mm
- Example column
- Dallmeier F250-4500-S