DE
ETEC 4030/PC/SPD, opened: mounting plate with switch, power supply, protective
             devices and splice cassette

Drag to rotate

Fibre-optic video connection box · AK(S)43-4PXX

4030/PC/SPD

Four IP cameras over a single fibre. Power supply and protective devices are on the plate when it leaves us, the place for the switch is prepared — tested before the box leaves the works.

Scroll

Let's open
it up.

Five components — tap one to read about it.

Everything
in its place.

Free DIN rails on the galvanised mounting plate of the ETEC 4030/PC/SPD: the space prepared for the switch, the wiring duct on the left
01

Room for the switch

The switch is not included in the delivery; its place on the rail is prepared: for an industrial PoE switch with up to six ports and up to 165 × 200 × 165 mm. For example the barox PC-PITE502-GBTE or RY-LPIGE-602GBTME.

Corner of the open ETEC 4030/PC/SPD: door edge and polycarbonate housing rim, the power supply inside at the top
02

Material

Enclosure in polycarbonate, halogen-free, UV- and weather-resistant, in RAL 7035 (custom paint finish possible), or in stainless steel V2A / V4A. Inside, a mounting plate of galvanised steel with DIN rails and wiring ducts. Approved from −40 to +80 °C.

Mains input in the ETEC 4030/PC/SPD: terminal blocks for PE, N and L, next to them the circuit breaker and the surge protector
03

Mains connection

The mains input comes in through an M20 gland onto 4-conductor terminals with a double connection: 2 × L, 2 × N, 2 × PE. The power supply delivers 24 or 48 V on the secondary side, at 120, 240 or 480 W.

Four M20 and four M25 polyamide cable glands with sealing inserts
04

Cable glands

Every cable has an opening of its own, all on the underside: 4 × M20 for the mains input, the optical fibre and two spares, 4 × M25 for the LAN patch cables — with a split inner seal (IP 66) so that the RJ45 plug fits through — and two pressure-equalising elements as standard. Anything unused gets a blanking plug.

ETEC 4030/PC/SPD closed and wall-mounted with four wall brackets
05

Mounting

On a wall via wall angle brackets, on a pole via V2A clamping bands up to Ø 300 mm. For locations without shade the SD-V2A-ARCA4030 weather roof is available as an accessory.

Installation location

Wall and pole

Outdoors on a wall or pole, up to 300 mm diameter.

Technical data

Per data sheets 4030/PC/SPD and 4030/PC/SO · version 10.26 · subject to change

Enclosure

01standardDimensions

Standard
400 × 300 × 210 mm W × H × D

02variableMaterial

Opt. 01
Polycarbonate IP66, IK10, halogen-free, −40 °C … +80 °C
Opt. 02
Stainless steel V2A / V4A IP66, IK10, −40 °C … +80 °C

03variableLocking mechanism

Opt. 01
Swing-handle lock prepared for a half-profile cylinder, 2-point locking
Opt. 02
Quarter-turn lock double-bit operated, 2-point locking

Mechanical configuration

01standardMounting plate

Standard
Steel, galvanised incl. DIN rails & wiring ducts

02standardCable entries underside

Standard
4 × M20 mains input / fibre / 2 × spare
Standard
4 × M25 incl. split inner seal (IP66) / RJ45 connection
Standard
2 × pressure-equalisation element

Active network component

01not includedIndustrial PoE switch

Example
barox PC-PITE502-GBTE
Example
barox RY-LPIGE-602GBTME
Example
Any active network component / switch max. 165 × 200 × 165 mm, W × H × D

02standardFibre connection

Standard
Splice cassette incl. splice comb / 12 fibres

Electrical configuration

01standardMains input terminals 4-conductor terminals

Standard
Double connection 2 × L / 2 × N / 2 × PE

02standardSurge arrester

Standard
Two-pole single-phase TN systems

03standardCircuit protection

Standard
Miniature circuit breaker type B10(A)

04variablePower supply

Options
Secondary 24 V / 48 V 120 W / 240 W / 480 W

05variableFuse terminal

Options
Secondary fuse 24 V / 48 V

06standardDouble-level terminals 2-conductor terminals

Standard
2 × magnetic contact connection

07standardTamper contact

Standard
Magnetic contact switch protection against unauthorised opening

08variableEthernet surge arrester

Options
up to 4 × protection of Ethernet connections

Electrical configuration

01standardMains input terminals 4-conductor terminals

Standard
Double connection 2 × L / 2 × N / 2 × PE

02standardCircuit protection

Standard
RCBO type B16(A) / tripping current 30 mA

03standardService socket

Standard
SCHUKO socket service & installation use

04variablePower supply

Options
Secondary 24 V / 48 V 120 W / 240 W / 480 W

05variableFuse terminal

Options
Secondary fuse 24 V / 48 V

06standardDouble-level terminals 2-conductor terminals

Standard
2 × magnetic contact connection

07standardTamper contact

Standard
Magnetic contact switch protection against unauthorised opening

08variableEthernet surge arrester

Options
up to 8 × protection of Ethernet connections

Ready for the 4030/PC/SPD?

We configure the box for your project — number of cameras, protective devices, mounting type, weather protection.

Hanauerstraße 15 · 75181 Pforzheim · Mon–Fri 9 am–5 pm