DE
ETEC 5040/PC/CORE, opened: mounting plate with power supply, circuit breakers
             and surge protector, the DIN rails for the switch left free

Drag to rotate

Fibre-optic video connection box · AK(S)54-8P-XX

5040/PC/CORE

Up to eight IP cameras over a single fibre. Assembled, wired and tested — before the box leaves the works.

Scroll

Take a
closer look.

Five components — tap one to read about it.

Thought through
as one piece.

Inside of the ETEC 5040/PC/CORE door: pivot of the swing handle with the two connecting rods of the 2-point locking
01

Locking mechanism

There is a choice of a swing handle, prepared for a half-profile cylinder, or a quarter-turn lock with double-bit operation — both pull the lid against the all-round seal with 2-point locking. That carries IP 66 and IK 10. A magnetic contact in the lid frame reports every opening to the control centre via a volt-free contact: unauthorised access does not go unnoticed.

Corner of the open ETEC 5040/PC/CORE: door edge and polycarbonate housing rim, the power supply inside at the top
02

Material

Enclosure in polycarbonate, halogen-free and UV-stable, in RAL 7035 (custom paint finish possible), or in stainless steel V2A / V4A. Inside, a galvanised steel mounting plate with DIN rails and wiring ducts. Temperature range −40 to +80 °C.

Mains input in the ETEC 5040/PC/CORE: terminal blocks for L, N and PE with connected wires, the surge protector on the right
03

Mains connection

The mains input lands on 4-conductor terminals with a double connection: 2 × L, 2 × N, 2 × PE. The power supply delivers 24 or 48 V on the secondary side, at 120, 240 or 480 W — depending on the number and power class of the cameras.

RCBO on the DIN rail in the ETEC 5040/PC/CORE, the service socket to its right
04

Protective devices

Fitted as standard: an RCBO B16 with 30 mA tripping current, a B10 circuit breaker and a two-pole surge protector. Everything sits on the rail in a fixed position — what is fitted is stated in the test report.

SCHUKO service socket on the DIN rail in the ETEC 5040/PC/CORE
05

Socket

A SCHUKO service socket inside the enclosure as standard: a laptop, a test instrument or a soldering iron for the splicing work all run off the mains on site, without a second supply having to be brought to the location.

Installation location

Wall and pole

Outdoors on a wall or pole, up to 300 mm diameter.

Technical data

Per data sheet 5040/PC/CORE · version 10.26 · subject to change

Enclosure

01standardDimensions

Standard
500 × 400 × 210 mm W × H × D

02variableMaterial

Opt. 01
Polycarbonate IP66, IK10, halogen-free, −40 °C … +80 °C
Opt. 02
Stainless steel V2A / V4A IP66, IK10, −40 °C … +80 °C

03variableLocking mechanism

Opt. 01
Swing-handle lock prepared for a half-profile cylinder, 2-point locking
Opt. 02
Quarter-turn lock double-bit operated, 2-point locking

Mechanical configuration

01standardMounting plate

Standard
Steel, galvanised incl. DIN rails & wiring ducts

02standardCable entries underside

Standard
4 × M20 mains input / fibre / 2 × spare
Standard
8 × M25 incl. split inner seal (IP66) / RJ45 connection
Standard
2 × pressure-equalisation element

Active network component

01not includedIndustrial PoE switch

Example
barox RY-LPITE-802GBTME
Example
barox LT-LPIGE-802GBTME
Example
Any active network component / switch max. 200 × 250 × 165 mm, W × H × D

02standardFibre connection

Standard
Splice cassette incl. splice comb / 12 fibres

Electrical configuration

01standardMains input terminals 4-conductor terminals

Standard
Double connection 2 × L / 2 × N / 2 × PE

02standardSurge arrester

Standard
Two-pole single-phase TN systems

03standardCircuit protection

Standard
RCBO type B16(A) / tripping current 30 mA

04standardCircuit protection

Standard
Miniature circuit breaker type B10(A)

05standardService socket

Standard
SCHUKO socket service & installation use

06variablePower supply

Options
Secondary 24 V / 48 V 120 W / 240 W / 480 W

07variableFuse terminal

Options
Secondary fuse 24 V / 48 V

08standardDouble-level terminals 2-conductor terminals

Standard
2 × magnetic contact connection

09standardTamper contact

Standard
Magnetic contact switch protection against unauthorised opening

10variableEthernet surge arrester

Options
up to 8 × protection of Ethernet connections

Ready for the 5040/PC/CORE?